# Protobuf: how a message is written on the wire

> How Protocol Buffers turns a message into bytes, one field at a time, worked through byte by byte, from varints and tags to strings, negative numbers and missing fields, and how a reader skips fields it does not know.

Page: https://structure.fi/guides/protobuf-wire-format/

Protocol Buffers (Protobuf) is Google's binary format for structured messages. A schema file (`.proto`) declares each message's fields, and gives every field a **field number** that never changes. The bytes on the wire carry those numbers, not the field names, and not the offsets a format like SBE uses ([fields and padding](https://structure.fi/guides/binary-message/#fields-and-padding)).

This article writes one small message by hand, byte by byte: an order acknowledgement whose `.proto` file declares three fields.

The message OrderAck: its fields as the schema declares them, and the values written below:

| Field number | Name | Type | Value |
| --- | --- | --- | --- |
| 1 | order_id | int64 | 9001 |
| 2 | order_list_id | optional int64 | empty |
| 3 | symbol | string | BTCUSDT |

The whole message is 12 bytes:

OrderAck as Protobuf writes it; each row's offset counts from the message's first byte:

| Offset | Bytes | Holds | Note |
| --- | --- | --- | --- |
| 0 | `08` | tag | field 1 (order_id), a varint follows |
| 1 | `a9 46` | order_id | 9001 as a varint |
| 3 | `1a` | tag | field 3 (symbol), a length follows |
| 4 | `07` | length | 7 bytes follow |
| 5 | `42 54 43 55 53 44 54` | symbol | BTCUSDT |

`order_list_id` is not there at all: an empty field writes nothing ([null values](https://structure.fi/guides/binary-message/#null-values)). The sections below explain each row.

## Records: a tag, then a value

A Protobuf message is a run of **records**, one per field that has a value. Each record is a **tag**, which says which field this is and how its value is written, followed by the value. There is no header with the message's length and no end marker: the message ends where its bytes end ([framing](https://structure.fi/guides/binary-message/#framing) covers how a stream separates messages).

Because every record names its own field, the order of records does not matter, a field the reader has never heard of can be skipped, and a field nobody set costs no bytes.

## Varints: integers in as few bytes as they need

Most integers, the tags themselves included, are written as **varints** (variable-length integers). A small number takes one byte; a large one takes more. The rule:

1. Write the number in binary and cut it into groups of 7 bits, starting from the lowest bits.
2. Write the groups lowest first, one per byte, in the low 7 bits of the byte.
3. Set the byte's top bit (the eighth) to `1` if another byte follows, and to `0` on the last byte.

Take `9001`. In binary it is `10001100101001`, 14 bits, so it splits into two groups of 7:

9001 as a varint: two 7-bit groups, lowest first, each in a byte whose top bit says whether another follows:

| Group | Its 7 bits | Its value | Top bit | Byte in binary | Byte in hex |
| --- | --- | --- | --- | --- | --- |
| lowest | 0101001 | 41 | 1, another byte follows | 1 0101001 | a9 |
| next | 1000110 | 70 | 0, the last byte | 0 1000110 | 46 |

A reader does the reverse. It reads `a9`, sees the top bit set, keeps the low 7 bits (`0101001`, 41) and reads on. It reads `46`, sees the top bit clear, keeps its 7 bits (`1000110`, 70) and stops. Then it puts the groups back in order, highest first: `1000110` followed by `0101001` is `10001100101001`, which is 9001.

Each group is worth 128 times the one before it, because 7 bits hold the values 0 to 127. So the second group counts 128s: 70 × 128 + 41 = 8960 + 41 = 9001. A third group would count 128 × 128 = 16384s, and so on.

The cost of this compactness is that a reader cannot jump to a field: it has to read each varint to find where the next record starts.

How many bytes a varint takes:

| Values | Bytes |
| --- | --- |
| 0 to 127 | 1 |
| 128 to 16,383 | 2 |
| 16,384 to 2,097,151 | 3 |
| up to 2^64 − 1 | up to 10 |

## Tags: field number and wire type

The tag is a varint too. It packs two things into one number: the **field number**, shifted left by 3 bits, and a 3-bit **wire type** in the lowest bits:

`tag = field number × 8 + wire type`

The first tag of the message, `08`, is `1 × 8 + 0`: field 1, wire type 0. The second, `1a` (26), is `3 × 8 + 2`: field 3, wire type 2. Field numbers 1 to 15 fit in a one-byte tag, which is why schemas give their most frequent fields the smallest numbers.

## Wire types: how long a value is

The wire type does not say what the value means (that is in the schema); it says how the value is laid out, so that any reader, with or without the schema, knows where the value ends:

The wire types and what a reader skips for each:

| Wire type | Name | Used for | Where the value ends |
| --- | --- | --- | --- |
| 0 | VARINT | int32, int64, uint32, uint64, sint32, sint64, bool, enum | at the first byte whose top bit is 0 |
| 1 | I64 | fixed64, sfixed64, double | after 8 bytes |
| 2 | LEN | string, bytes, nested messages, packed repeated fields | a varint length comes first, then that many bytes |
| 5 | I32 | fixed32, sfixed32, float | after 4 bytes |

(Wire types 3 and 4 marked the start and end of "groups", an old feature that is deprecated.)

This table is what makes Protobuf easy to evolve: a reader built before field 3 existed still reads its tag, sees wire type 2, reads the length `07`, and skips 7 bytes to the next record ([schema versioning](https://structure.fi/guides/schema-versioning/)). Fixed-width numbers (`I64`, `I32`) are always little-endian ([endianness](https://structure.fi/guides/binary-message/#endianness)).

## Strings, bytes and nested messages

A `LEN` value is a varint length followed by that many bytes. For `symbol`, that is `07` and the seven ASCII bytes of `BTCUSDT`. A nested message is written the same way: its own records, prefixed by their total length, so a reader can skip the whole nested message in one step ([variable-sized data and lists](https://structure.fi/guides/variable-sized-data/)).

## Negative numbers

A varint stores an unsigned number. An `int64` of `−5` is stored as the 64-bit two's complement pattern, which has its top bit set, so it always takes the full 10 bytes:

−5 in an int64 field: ten bytes, because the number's top bits are all ones:

| Offset | Bytes | Holds | Note |
| --- | --- | --- | --- |
| 0 | `fb ff ff ff ff ff ff ff ff 01` | value | −5 as int64 |

The `sint32` and `sint64` types avoid this with **ZigZag** encoding, which interleaves negative and positive numbers before writing the varint: 0 → 0, −1 → 1, 1 → 2, −2 → 3, 2 → 4, and so on. `−5` becomes `9`, one byte (`09`). A schema uses `sint64` for fields that are often negative, such as price changes, and `int64` for ones that rarely are, such as ids.

## Missing fields and default values

An empty field writes no record, so a reader that finds no record for a field has to decide what that means:

- A field declared `optional`, and any field whose type is a message, has **explicit presence**: the reader can tell "not set" apart from a value, as `order_list_id` above.
- A plain scalar field in proto3 has **implicit presence**: the writer also leaves it out when it holds its default, `0` or `""`, so a reader cannot tell "set to 0" from "not set".

This is the second of the three ways to write a missing value in [null values](https://structure.fi/guides/binary-message/#null-values): tag the fields and leave the empty ones out.

## Sources

- https://protobuf.dev/programming-guides/encoding/
- https://protobuf.dev/programming-guides/field_presence/
- https://protobuf.dev/programming-guides/proto3/#updating

Reviewed by Structure on 2026-11-24. Last changed 2026-11-24.
