# SBE: variable-length data fields

> Learn how SBE encodes variable-length strings and raw byte payloads as length-prefixed data fields, why they must sit last in a message or group entry, and how they behave across versions.

Page: https://structure.fi/guides/sbe-variable-length-data/

Simple Binary Encoding (SBE) is the FIX Trading Community's binary format for low-latency market data and order entry ([how an SBE message is laid out](https://structure.fi/guides/sbe-message-layout/)). SBE achieves fast decoding by placing fixed-size fields—prices, quantities, timestamps—at constant byte offsets known from the schema. Real trading messages still carry values whose byte length changes from message to message, such as ticker symbols (`BTCUSDT` vs `ETHBTC`), client order ids, or nested binary payloads ([variable-sized data and lists](https://structure.fi/guides/variable-sized-data/)).

SBE encodes those values as **variable-length data fields** (`<data>` in the XML schema): an unsigned length prefix immediately followed by that many bytes. This page explains how SBE declares data fields as two-part composites, why they must always sit after all fixed fields and repeating groups, and what to watch for when schemas evolve.

## Seeing data fields in Binance's SBE samples

In `TradesStreamEvent` (bundled Binance Spot Streams sample), `symbol` sits at the very end after the `trades` repeating group. The Market Data Visualizer lays out every data field as empty (0 payload bytes), so each `Data` row's size equals its length prefix (1 byte for `varString8`).

Layout of TradesStreamEvent in the Binance Spot Streams SBE schema, as the Market Data Visualizer lays it out:

| Offset | Size | Name | Type | Presence | Since |
| --- | --- | --- | --- | --- | --- |
| 0 | 18 | TradesStreamEvent | block |  | 0 |
| 0 | 8 |  eventTime | utcTimestampUs | required | 0 |
| 8 | 8 |  transactTime | utcTimestampUs | required | 0 |
| 16 | 1 |  priceExponent | exponent8 | required | 0 |
| 17 | 1 |  qtyExponent | exponent8 | required | 0 |
| 18 | 6 |  trades | group groupSizeEncoding |  | 0 |
| 18 | 2 |   .blockLength | uint16 |  |  |
| 20 | 4 |   .numInGroup | uint32 |  |  |
| 24 | 25 |   [0] | entry |  |  |
| 24 | 8 |    .id | tradeId | required | 0 |
| 32 | 8 |    .price | mantissa64 | required | 0 |
| 40 | 8 |    .qty | mantissa64 | required | 0 |
| 48 | 1 |    .isBuyerMaker | enum boolEnum | required | 0 |
| — | 0 |    .isBestMatch | const enum boolEnum | constant | 0 |
| 49 | 1 |  symbol | data varString8 |  | 0 |

[Open the symbol data field in the Market Data Visualizer's layout](https://structure.fi/tools/market-data-visualizer/app/#open?sample=binance-stream&node=m10000%2Fd200&place=layout&guide=sbe-variable-length-data&section=block-5)

Data fields also appear inside repeating group entries—for example, `commissionAsset` inside each `fills` entry of `NewOrderFullResponse` in the bundled Binance Spot API sample—and can carry raw binary blobs such as a nested SBE message (`result` of type `messageData` in `WebSocketResponse`).

## The length prefix

A data field's type is a two-member [composite](https://structure.fi/guides/sbe-schema-file/#composites):

- `length`: unsigned integer giving the payload byte count.
- `varData`: the payload bytes, declared with `length="0"` to mean variable length.

The schema chooses the width of `length` to fit the data. In Binance's schemas, short strings such as `symbol` use `varString8` (1-byte `uint8` length + UTF-8 bytes), whereas `WebSocketResponse/result` uses `messageData` (4-byte `uint32` length + raw bytes). Always inspect the composite instead of assuming a width.

[Open varString8 in the Market Data Visualizer](https://structure.fi/tools/market-data-visualizer/app/#open?sample=binance-stream&node=t%2FvarString8&place=detail&guide=sbe-variable-length-data&section=block-15)

## Why data fields come last

Both at the message root and inside each [repeating group](https://structure.fi/guides/variable-sized-data/#sbe-count-prefixed-groups-and-length-prefixed-data) entry, SBE requires fixed-size fields first, repeating groups second, and data fields last. Putting data fields last keeps every fixed-size field at a constant schema offset; if a fixed field followed a data field, its offset would shift on every message.

The tradeoff is sequential reading: in `NewOrderAckResponse` (which has two trailing data fields, `symbol` then `clientOrderId`), a decoder must read `symbol`'s length prefix and skip its bytes before it can reach `clientOrderId`. Generated decoders enforce reading groups and data fields in schema order.

## Data fields and versions

Newer schema versions may only append new data fields after existing ones at the same level, marked with `sinceVersion` ([schema versioning](https://structure.fi/guides/schema-versioning/)).

- **At the end of a message:** safe—older decoders stop after the data fields they know.
- **Inside a group entry:** safe only if the group's dimension header includes `numVarDataFields` ([the message header](https://structure.fi/guides/sbe-message-header/#the-four-fields)). Without that count, an older decoder cannot skip the unknown data field to find the next entry.

## What to check when decoding

- Check the width of `length` in the schema's data composite (`uint8`, `uint16`, or `uint32`) and its `characterEncoding`.
- Always read data fields strictly in schema order—never seek ahead by a fixed offset after the first data field.
- Validate `length` against the remaining buffer or framing length before reading `varData`.

See [how an SBE message is laid out](https://structure.fi/guides/sbe-message-layout/) for how data fields fit into the full message.

## Sources

- https://www.fixtrading.org/standards/sbe/
- https://github.com/FIXTradingCommunity/fix-simple-binary-encoding/blob/master/v1-0-STANDARD/doc/02FieldEncoding.md
- https://github.com/FIXTradingCommunity/fix-simple-binary-encoding/blob/master/v1-0-STANDARD/doc/03MessageStructure.md
- https://github.com/real-logic/simple-binary-encoding/wiki/FIX-SBE-XML-Primer

Reviewed by Structure on 2026-11-24. Last changed 2026-11-23.