Parquet: encodings and compression

Learn what Apache Parquet is, why columnar storage splits encoding from compression, how each encoding and codec works, and why those choices change file size and read speed.

View as Markdown

Apache Parquet is an open binary file format for tabular data—rows and columns, like a trade blotter or historical quote log—that stores values column by column rather than row by row (how a Parquet file is laid out). Researchers, data engineers, and trading firms use it to archive market-data history and run fast analytical queries over millions of rows.

Storing one column contiguously puts values of the same type—and usually similar values—right next to each other. In a trades table, the symbol column repeats "BTCUSDT" thousands of times, price values hover near one another, and ts_recv timestamps rise monotonically. That structure lets Parquet shrink a column chunk in two separate passes:

  1. Encoding uses knowledge of the column's type and data patterns to represent its values compactly—for example, replacing repeated ticker strings with tiny integer dictionary codes, or storing only the small differences between consecutive timestamps.
  2. Compression then runs a general-purpose byte compressor (such as ZSTD or Snappy) over each encoded page body, leaving page headers uncompressed so readers can skip pages without decompressing them.

This page explains each encoding and compression codec Parquet supports, how to inspect them in the Market Data Visualizer, and why two Parquet files holding the same rows can differ in size and read speed. The footer records the encodings and codec used for every column chunk; see how a binary message is put together and prices and money in binary for how Parquet handles byte order, nulls, and decimals.

Seeing encodings and codecs in the trades sample

Open the trades sample's File layout view and expand row groups rg0–rg4 into column chunks c0–c9. Every chunk uses ZSTD. Every column except boolean is_buy uses a dictionary—for example, rg0/c2 (symbol) starts with a dict page and lists PLAIN, RLE, RLE_DICTIONARY (PLAIN for the dictionary page, RLE for levels, RLE_DICTIONARY for data-page indices), while rg0/c9 (is_buy) lists only PLAIN, RLE.

Open the trades sample's column chunks and pages

Open the symbol column's details

On very small chunks, compression overhead can outweigh savings: rg0/c2 is 478 bytes uncompressed and 536 bytes compressed.

Plain

PLAIN writes values back to back with no transformation: fixed-width types in little-endian order (8 bytes for INT64), BYTE_ARRAY as a 4-byte length plus bytes, and BOOLEAN packed 1 bit per value. Every reader supports PLAIN, and writers fall back to it for high-cardinality or random columns.

Dictionary

Dictionary encoding stores each distinct value once in a PLAIN dictionary page at the start of the chunk, then stores compact integer indices in the data pages—ideal for repeating values like ticker symbols.

  • RLE_DICTIONARY is the current name; PLAIN_DICTIONARY is deprecated but still appears in older files. Both encode indices with the RLE/bit-packing hybrid below.
  • If a dictionary grows past its size or cardinality cap, the writer switches the remaining pages of that chunk to PLAIN. The app flags dictionary fallback in its Parquet checks.

RLE and bit-packing

RLE is a hybrid of run-length encoding and bit-packing for small unsigned integers, using only as many bits per value as the maximum requires. It alternates between:

  • Repeated runs: one value and its repeat count.
  • Bit-packed runs: a block of distinct values packed tightly at a shared bit width.

Parquet uses this hybrid for dictionary indices, optional booleans, and repetition/definition levels on data pages. In an optional column such as price (max_definition_level = 1), definition levels record which rows are non-null so nulls take no space in the value stream; with no nulls, the levels collapse into one repeated run (null values in Parquet). The older BIT_PACKED encoding is deprecated.

Delta encodings

Delta encodings store differences between consecutive values, suiting sorted or slowly changing columns like timestamps and sequence numbers:

  • DELTA_BINARY_PACKED (INT32, INT64): first value, then block-level bit-packed deltas relative to each block's minimum delta.
  • DELTA_LENGTH_BYTE_ARRAY (BYTE_ARRAY): delta-encoded string lengths followed by concatenated string bytes.
  • DELTA_BYTE_ARRAY (BYTE_ARRAY, FIXED_LEN_BYTE_ARRAY): shared-prefix length with the previous value plus the differing suffix—strong on sorted keys and URLs.

Byte stream split

BYTE_STREAM_SPLIT transposes fixed-width values (FLOAT, DOUBLE, INT32, INT64, FIXED_LEN_BYTE_ARRAY) so all first bytes sit together, then all second bytes, and so on. It does not shrink data alone, but grouping similar bytes lets the subsequent compression codec achieve better ratios.

ALP

ALP (Adaptive Lossless Floating-Point) encodes FLOAT and DOUBLE values that are actually decimals as scaled integers while keeping exact bits for exceptions. Verify reader support before writing ALP; for prices that must be exact, prefer a decimal column (prices and times as integers).

Compression codecs

Each column chunk chooses one codec (most writers use one codec file-wide), applied to page bodies only:

  • UNCOMPRESSED: raw encoded bytes.
  • SNAPPY: Google's Snappy format.
  • GZIP: RFC 1952 GZIP (not raw zlib/deflate).
  • ZSTD: Zstandard (RFC 8878).
  • LZ4_RAW: LZ4 block format.
  • BROTLI: RFC 7932 Brotli.
  • LZO: LZO library format.
  • LZ4: deprecated (undocumented framing, incompatible across implementations; use LZ4_RAW).

For every codec except LZO and LZ4, the Parquet specification designates a reference library to settle ambiguities.

How the app shows them

Select any column chunk in the File layout view to read its codec, encodings, compressed vs uncompressed sizes, dictionary page offset, and individual pages in the Detail pane. Check the column's physical and logical types in the schema: PLAIN and dictionary apply to any type, while delta, byte stream split, and ALP apply only to the types listed above.

What to check when sizing files

  • Compare total_uncompressed_size and total_compressed_size per chunk in Detail—if compressed is larger, row groups may be too small.
  • Look for dictionary encoding fell back to plain in Diagnostics on high-cardinality columns such as order ids or timestamps, where delta encoding or disabling dictionary helps.
  • Avoid deprecated PLAIN_DICTIONARY, BIT_PACKED, and LZ4 when configuring writers.

See how a Parquet file is laid out for where chunks, pages, and the footer sit in the file.

Sources

Reviewed by Structure on 2026-11-24. Last changed 2026-11-26.